TYPICAL SCENARIOS28 parts, 28 ways to measure
Each entry follows public standards: the part and the problem first, then how we measure, which standard applies, and what came out. Deliberately free of marketing language — compare it with your own part.
01Automotive
Carburised gears: disputed case depth
- Part
- 20CrMnTi carburised gear, module 3, 0.6–0.9 mm required
- Problem
- Supplier measured 0.82 mm, OEM re-checked 0.61 mm — two verdicts on one batch, line stopped pending arbitration.
- Approach
- ZHVST-30F micro-Vickers system with motorised stage; one point every 0.05 mm from the surface per GB/T 9450, depth taken at 550 HV. Specimens cut on the ZQ-300F, mounted in the ZXQ-50, polished on the ZMP-3000.
- Standard
- GB/T 9450, ISO 2639
- Outcome
- Both parties re-measured on the same machine, specimen and parameters; spread narrowed to 0.03 mm and the case closed in three days without rejecting the batch.
02Bearings
Rings: sampling rate cannot keep up
- Part
- GCr15 bearing rings, 50,000 pcs/month
- Problem
- Only three parts were hardness-tested — under 5% coverage — and soft spots surfaced at assembly.
- Approach
- HRS-150 digital Rockwell tester gives a direct HRC reading in 8 s per part; suspect parts go to the ZQ-300F for sectioning and the 4XC-ST for structure review. Hardness distribution logged per furnace load.
- Standard
- GB/T 230.1, GB/T 18254
- Outcome
- Coverage raised to 30% while cost per part fell; soft batches are now stopped in heat treatment.
03Aerospace
Thermal-spray coatings: cross-section hardness and bonding
- Part
- Superalloy substrate with WC-Co / ceramic coating, 150–400 μm
- Problem
- Surface hardness alone cannot reveal internal porosity or interfacial cracks, so spalling stayed unexplained.
- Approach
- ZQ-300F low-speed precision cutting prevents edge chipping, ZXQ-50 cold mounting protects the edge, ZMP-3000 prepares the section stepwise, and the 4XC-ST inspects the interface. ZHVST-30F with 50 gf measures every 20 μm across the section.
- Standard
- GB/T 4340.1, ASTM E384, GB/T 9796
- Outcome
- A three-zone hardness profile (coating, interface, substrate) quantified the porous layer, giving spray parameters a comparable basis.
04Fasteners
High-strength bolts: decarburisation and brittle failure
- Part
- Grade 10.9 M12 bolts, quenched and tempered
- Problem
- Brittle fracture after three months in service with no visible defect — decarburisation suspected but unproven.
- Approach
- ZQ-300F sections along the axis, ZXQ-50 protects the thread root, ZMP-3000 polishes, and the 4XC-ST measures decarburisation depth; ZHVST-30F runs a 20 gf gradient from the surface. Judged to GB/T 3098.1.
- Standard
- GB/T 3098.1, ISO 898-1, GB/T 224
- Outcome
- Full decarburisation of 0.06 mm at the thread root confirmed an atmosphere problem; 120,000 bolts in the batch were screened.
05Mould & die
H13 cavities: hardness lost during polishing
- Part
- H13 die-casting cavity, 46–50 HRC required
- Problem
- Occasional early washout after polishing, yet every incoming hardness report passed — the culprit process stayed hidden.
- Approach
- HVS-5 Vickers tester takes 1 kgf points on the cavity surface and on polished areas; ZMP-3000 re-polishes and the 4XC-ST checks for tempering from overheating. Hardness compared at identical positions before and after polishing.
- Standard
- GB/T 4340.1, NADCA #207
- Outcome
- Excess polishing pressure had softened the surface by 3–4 HRC; switching to low pressure and multiple passes cut washout by 70%.
06Third-party labs
Angle metrology: traceable autocollimator readings
- Part
- Granite surface plates and machine guideways, straightness / flatness
- Problem
- Customers asked for an angle certificate with uncertainty; the existing optical instruments could not be traced.
- Approach
- ZY-20 autocollimator (±60″ / 0.2″) with a bridge plate in steps, straightness evaluated by minimum zone; a polygon prism cross-checks the instrument to build an internal calibration chain.
- Standard
- JJF 1110, GB/T 20920, JJG 117
- Outcome
- Certificates are accepted directly by customers, the internal calibration interval went from fixed half-yearly to on-demand, and outsourcing costs fell by two thirds.
07Forging
Large shafts: cutting distortion scraps the specimen
- Part
- 42CrMo forged shaft, Ø180 mm × 1.2 m
- Problem
- An ordinary abrasive saw left blue temper colours and a 1.5 mm taper; 3 mm had to be ground away and the specimen was effectively lost.
- Approach
- Moved to a ZQ-500F with a large wheel, dual coolant and 1.5 mm/min feed, sectioned in steps with both ends supported; faces finished on a ZY-200.
- Standard
- GB/T 13298, ASTM E3
- Outcome
- Taper within 0.2 mm and no temper colours; preparation time fell from 40 to 15 minutes per piece.
08Battery & electronics
Electrode foils: any blade curls the edge
- Part
- 8 µm copper and 12 µm aluminium foils, coated and uncoated zones
- Problem
- Abrasive cutting curled the foil and peeled the coating, so thickness and interface could not be measured.
- Approach
- ZY-100E diamond wire saw at low feed with no mechanical squeezing, held in a chilled fixture, then cold mounted.
- Standard
- GB/T 13298, ISO 19700
- Outcome
- Straight cut, no curl, intact coating interface; coating thickness and interface defects became measurable.
09Cemented carbide
YG grades: cobalt pools dragged out by polishing
- Part
- YG8 inserts, 1.5 µm grain size
- Problem
- Hand polishing with too much force removed cobalt and left pits that were read as porosity; batches did not agree.
- Approach
- A ZMP-3000 one-touch program with resin-bond diamond discs, low force, short steps and a 1 µm diamond finish, verifying each step under the microscope.
- Standard
- GB/T 3488, ISO 4499
- Outcome
- Cobalt pools preserved and porosity ratings repeatable within 0.2 of a class across three specimens.
10Heat treatment
Nitrided layers: the edge is always rounded away
- Part
- 38CrMoAl nitrided piston rod, case 0.25 mm
- Problem
- After mounting the edge was chamfered and the compound layer vanished, so case depth read 30% low or not at all.
- Approach
- ZXQ-50 hot mounting to protect the edge, ZMP-1000 with soft cloths below 10 N for 60 s per step, ZD-300 vibratory polishing for the final finish.
- Standard
- GB/T 11354, ISO 6336
- Outcome
- Edge retention clearly improved and case depth repeated within 0.02 mm.
11Fasteners & wire
M6 bolts: the thread root disappears
- Part
- Grade 10.9 M6 bolts, 1 mm pitch
- Problem
- Specimens were too small to hold and the root was polished flat, so decarburisation and folds could not be judged.
- Approach
- Six pieces mounted at once in ZXQ-50 with phenolic at 140 °C and 25 MPa, ground to the pitch diameter and etched.
- Standard
- GB/T 3098.1, GB/T 224
- Outcome
- Root profile preserved, decarburisation and folds visible, 30 minutes for a batch of six.
12Casting
Heavy castings: bulk hardness will not settle
- Part
- HT250 machine-tool bed, 1.8 t, critical faces already machined
- Problem
- A portable Leeb gauge scattered on the rough face and disagreed with the foundry by 30 HBW.
- Approach
- HBT/HBST-3000 with a prepared Ø60 flat, 10 mm ball, 3000 kgf, 15 s dwell, indentation read by the image system.
- Standard
- GB/T 231.1, ISO 6506-1
- Outcome
- Agreement within ±10 HBW; acceptance no longer depends on feel.
13Cutting tools
Coated tools: coating and substrate hardness must be separated
- Part
- Carbide end mill with 3 µm TiAlN coating
- Problem
- Measuring at 1 kgf punched through the coating into the substrate, so the coating was never characterised.
- Approach
- HVF-1000D at 0.05 kgf for the coating and 0.5 kgf for the substrate, with automatic indentation measurement and photo records; coating thickness measured in the same field.
- Standard
- GB/T 4340.1, ISO 6507-1
- Outcome
- Coating 2800 HV0.05 and substrate 1600 HV0.5, both traceable and comparable between deliveries.
14Springs
Spring steel: decarburisation halves fatigue life
- Part
- 60Si2Mn coil spring, 12 mm wire
- Problem
- Bench testing failed at 80,000 cycles from a surface origin while hardness passed, leaving no explanation.
- Approach
- Sectioned on a ZQ-50S, mounted in ZXQ-50 and traversed on an HVS-1000 every 0.05 mm, with 4XC-ST examination of the fully and partially decarburised zones.
- Standard
- GB/T 224, GB/T 18983
- Outcome
- Fully decarburised 0.05 mm and partially 0.12 mm; the atmosphere dew point was corrected and life returned to 300,000 cycles.
15Machine tools
Gantry guideways: a 3 m straightness dispute
- Part
- X-axis guideway, 3.2 m long
- Problem
- Spirit-level readings drifted with temperature and handling, and the builder and user disagreed by 0.02 mm/m.
- Approach
- ZY-30 autocollimator with a 200 mm bridge, 16 equally spaced points measured forward and back and evaluated by the minimum-zone method after a 2 h warm-up run.
- Standard
- GB/T 11336, ISO 230-1
- Outcome
- Both parties measured 0.018 mm full length, agreeing within 0.004 mm, and the machine was accepted first time.
16Construction
High-strength bolts: failure in the gripped thread
- Part
- M20 grade 10.9 bolts, tensile strength ≥1040 MPa
- Problem
- Specimens broke in the gripped thread, so the test was invalid even after changing grips.
- Approach
- WAW-600 hydraulic universal machine with bolt grips and an extensometer for Rp0.2, loaded at 10 MPa/s to GB/T 228.1.
- Standard
- GB/T 228.1, GB/T 3098.1
- Outcome
- Failure in the shank, 1085 MPa tensile and 940 MPa Rp0.2, usable for routine inspection.
17Welded structures
Low-temperature steel: impact energy falls off fast
- Part
- Q345E welded joint for −40 °C service
- Problem
- Room-temperature impact of 120 J passed, but without a transition curve the −40 °C behaviour was unknown.
- Approach
- JB-300B with a low-temperature bath, three specimens every 10 °C from +20 to −60 °C, plotted as energy against temperature.
- Standard
- GB/T 229, ISO 148-1
- Outcome
- Full transition curve obtained; 47 J at −40 °C against a 34 J requirement, and the welding procedure was frozen.
18Powder metallurgy
Sintered parts: porosity mistaken for inclusions
- Part
- Iron-base PM gear, 7.0 g/cm³ density
- Problem
- In bright field both pores and inclusions are black, so porosity was rated as inclusions and density was rejected.
- Approach
- 4XC-ST bright and dark field of the same field: pores glow in dark field and change with focus, inclusions do not; porosity then quantified by image analysis.
- Standard
- GB/T 5163, ISO 2738
- Outcome
- Separated true inclusions at class 0.5 from 6.8% porosity and avoided a wrongful rejection.
19Heat exchangers
Thin-wall tubes: flattened by the vice, ovality lost
- Part
- 20# steel heat-exchanger tube, φ19×2 mm, 300 mm long
- Problem
- Vice clamping plus abrasive cutting ovalised the tube end; wall thickness and roundness were unusable, while wire cutting could not get through.
- Approach
- ZQ-1000S auto-feed cutter with V-soft jaws and an internal mandrel, finer wheel, 0.8 mm/min feed, single-pass cutting without clamping distortion.
- Standard
- GB/T 13298, GB/T 246
- Outcome
- Ovality within 0.1 mm, wall thickness measurable, 3 min per cut.
20Automotive
Carburised gears: blue tint made the case look shallow
- Part
- 20CrMnTi carburised and hardened gear, 0.8 mm effective case
- Problem
- Insufficient cooling left temper colours at the cut; the case edge was softened and measured only 0.5 mm.
- Approach
- ZQ-300F with dual coolant jets straight into the cut, feed reduced to 1.2 mm/min with step feeding; 0.2 mm lightly ground off before measuring.
- Standard
- GB/T 9450, ISO 2639
- Outcome
- No temper colours; case re-measured 0.78 mm, matching the heat-treatment report.
21Surface engineering
Thermal-spray coatings: the whole layer lifted off
- Part
- WC-12Co coating, 300 μm, on 45# steel
- Problem
- Hot mounting opened the coating/substrate interface and the edge broke away during grinding, so thickness and porosity could not be measured.
- Approach
- Vacuum impregnation plus cold epoxy mounting, 24 h cure; wire-cut sectioning; minimum pressure and a final 1 μm step of only 20 s.
- Standard
- GB/T 9790, ASTM B748
- Outcome
- Interface intact, coating 305 μm, porosity 1.2%, no interfacial cracks.
22Non-ferrous
Copper: polished surface looks fogged
- Part
- T2 copper plate, 3 mm, grain size 30 μm
- Problem
- Mechanical polishing left a foggy surface with blurred boundaries; more pressure only smeared the second phase.
- Approach
- ZMP-1000 low-pressure program: 1200# then 3 μm diamond for 25 s and 0.05 μm silica for 10 s; etched in ferric chloride/HCl for 8 s.
- Standard
- GB/T 13298, GB/T 6394
- Outcome
- Mirror surface, clear boundaries, grain size 8.5, repeatable across three runs.
23Aerospace
TC4 titanium: scratches that will not go away
- Part
- TC4 titanium forging, 12 mm thick
- Problem
- Titanium smears and conducts heat poorly, so papers clogged quickly and every pass added scratches; water rinsing left drying marks.
- Approach
- ZMP-3000 with fresh papers, low pressure and 40 s per step; 3 μm diamond on short-nap cloth, ethanol rinse and warm-air dry.
- Standard
- GB/T 6611, ASTM E3
- Outcome
- Scratches removed, α/β interfaces clear, no drying marks.
24Welding consumables
Fine wires: one at a time is too slow
- Part
- φ0.8 mm flux-cored welding wire, 20 sections per batch
- Problem
- Single mounting was slow and the wires sat at an angle, so the polished plane missed the centre.
- Approach
- A shop-made 12-hole fixture loaded 12 wires at once into the ZXQ-50 hot press; the fixture keeps them parallel so one grind reaches all centres.
- Standard
- GB/T 13298, GB/T 17493
- Outcome
- 12 wires per press cycle, perpendicular sections, 20 wires in 40 min.
25Fasteners
Grade 12.9 bolt: decarburised depth kept measuring short
- Part
- M12 grade 12.9 bolt, hardened and tempered
- Problem
- The decarburised layer at the thread root is only tens of microns; indents spaced too widely missed the turning point and the depth was under-reported.
- Approach
- ZQ-50S precision cutting along the thread root, ZXQ-5A hot mounting for edge retention, ZMP-2000 to 1 μm; HVT-1000A HV0.5 indents every 0.05 mm from the root inwards, full + partial decarburisation judged per GB/T 224.
- Standard
- GB/T 224, GB/T 3098.1
- Outcome
- Full decarburisation 18 μm, total 42 μm — matching the metallographic cross-check, batch accepted.
26Advanced ceramics
Zirconia: too much polish pressure changed the hardness
- Part
- Y-TZP zirconia, 3Y-stabilised, 10×10×5 mm sintered tiles
- Problem
- Heavy polish pressure induced a tetragonal-to-monoclinic transformation layer; HV readings scattered low, giving "two hardnesses" in one batch.
- Approach
- ZY-100E low-speed diamond cutting, cold epoxy mounting; ZMP-2000 low-pressure long polish to 1 μm, HV1 measured unetched; indentation KIC for fracture toughness.
- Standard
- GB/T 16534, GB/T 6569
- Outcome
- Hardness stable at 1250±30 HV1, indentation KIC = 5.8 MPa·m^0.5, batch scatter under 5%.
27Electronics
MLCC capacitors: dielectric layers impossible to count
- Part
- 0402 MLCC, ~2 μm dielectric layers, 300+ layers
- Problem
- Chipping at the cut face fractured every layer in that zone — no way to count layers or measure thickness.
- Approach
- ZQ-50S slow precision cut, vacuum epoxy infiltration 12 h, ZMP-2000 stepwise diamond polish; layer thickness distribution measured at 1000× on the 6XC-ST image analysis system.
- Standard
- GB/T 13298, IEC 60384
- Outcome
- Intact cut face, dielectric thickness 1.9–2.2 μm uniform, no interlayer cracks found.
28Gears
Carburised gear: effective case depth acceptance
- Part
- 20CrMnTi carburised gear, module 4, case target 0.9 mm
- Problem
- The first sample was cut with a burnt face; the hardness gradient was wrong from the first point and the report was rejected.
- Approach
- ZQ-500F low-speed constant-torque cutting with flood cooling; HRC spot checks on the cut face before sectioning; HVST-1000C HV1 indents every 0.1 mm from the flank, effective depth at 550 HV1 per GB/T 9451.
- Standard
- GB/T 9451, GB/T 34807
- Outcome
- Effective case depth 0.86–0.92 mm, core hardness 42 HRC, smooth gradient, lot accepted.