Rockwell hardness
Measurement principle
A preliminary load F0 is applied, then the major load is added to reach the total load. After the major load is removed, the residual depth increase h is read in 0.002 mm units: HR = N − h/0.002. HRA/HRC use a 120° diamond cone (N=100); HRB uses a 1.5875 mm ball (N=130).
Where it applies
Hardened and tempered parts, finished parts after carburizing and quenching; the first choice for batch sampling — 5 seconds per part with an acceptable indentation.
Standard
Procedure
- 1Pick the scale: HRA or superficial HR15N for thin and case-hardened parts, HRC for hardened parts, HRB for annealed parts
- 2Specimen surface Ra ≤ 1.6 µm, flatness ≤ 0.02 mm, faces parallel, thickness at least 10× the indentation depth
- 3Keep centres ≥ 3d apart and ≥ 2.5d from the edge; average at least 3 points per part
- 4Check with a reference block each shift; re-calibrate if the error exceeds ±1.5 HRC
Common errors
- Back-face damage on thin walls reads 2–5 HRC low — always support the back face
- Testing directly on a curved surface: below 25 mm radius a correction is mandatory, otherwise readings run low